CD RNA HS Assay Kit

CAT Specs Inquiry Basket
NA004-01 100
NA004-02 500

CD RNA HS Assay Kit provides a fast, sensitive and accurate RNA fluorescence quantitative detection method. The Kit includes fluorescence detection reagents, buffers, and RNA standards. It has an excellent linearity between 5 ng and 100 ng for RNA samples, providing accurate quantification for initial sample concentrations from 250 pg /μl to 100 ng /μl. This kit is highly selective for total RNA, rRNA, mRNA, not affected by dsDNA. Meanwhile, most conventional contaminations, including salt, free nucleotides, proteins, solvents, and detergents are well-tolerated in the assay. The assay can be performed at room temperature. Before use, the fluorescence detection reagent(Equalbit RNA HS Reagent) should be diluted with its buffer(Equalbit RNA HS Buffer) into a working solution, and then add the Standard or RNA sample for detection by a Qubit fluorometer. All Kit components are subjected to stringent quality control.

The CD RNA HS Assay Kit is a quantitative RNA fluorescence detection technique that is quick, sensitive, and accurate. It has outstanding linearity for RNA samples between 5 and 100 ng, allowing for precise quantification of initial sample concentrations ranging from 250 pg/l to 100 ng/l. Total RNA, rRNA, and mRNA are highly selective for this kit, which is unaffected by dsDNA. It is useful for the quantitation of samples for microarray, RT-PCR, and Northern blot procedures

Workflow:

CD RNA HS Assay Kit Workflow
CD RNA HS Assay Kit Workflow

Storage:

The Kit can be stored at 2-8℃ for 6 months. And protect it away from light and avoid repeated freeze-thaw cycles.

Components:

CD RNA HS Assay Kit-Components

Specifications:

Sample amount 250 pg /μl-100 ng /μl
Features High sensitivity: Enable accurate quantification for initial sample concentrations from 250 pg /µL to 100 ng /µL. High specificity: Highly selective for total RNA, rRNA, mRNA, not affected by dsDNA and most conventional contaminations, including salt, free nucleotides, proteins, solvents, and detergents are well-tolerated. Easy operation: Dilute the fluorescence detection reagent with its buffer into a working solution, and then add the Standard or RNA sample for detection by a Qubit fluorometer. The assay can be performed at room temperature.
Sample type RNA

Note: This protocol is only suitable for Qubit® 2.0, Qubit® 3.0 and Qubit® 4.0 fluorimeters.

(1) All the kit components to room temperature before use.

(2) Prepare sufficient 0.5 ml PCR tubes to accommodate all samples and standards.

Note: Only 0.5ml PCR tubes are suitable for detection.

(3) Label the lid of each tube. DO NOT label on the side wall, in order to avoid any possible interference in fluorescence signal acquisition.

(4) Prepare fresh working solution of CD RNA HS Reagent, by diluting it in CD RNA HS Buffer according to a ratio of 1:200. DO NOT use glass containers for the preparation of working solution.

Note: A sufficient amount of working solution should be prepared to accommodate all samples and standards. For example, to accommodate 7 RNA samples and 2 standards, it is needed to prepare 2 ml of working solution by adding 10 μl of CD RNA HS Reagent to 1990 μl of CD RNA HS Buffer. Mix thoroughly by vortexing.

(5) Prepare standards. Load 190 μl of working solution to each tube used for standards, then carefully add exactly 10 μl of Standard #1 and Standard #2 to the corresponding tube, respectively. Gently vortex for 2-3 sec to avoid bubbles. Make sure the exact pipetting of 10 μl.

(6) Prepare samples. For each tube used for samples, add 180 μl - 199 μl of working solution, and then carefully add 1 μl - 20 μl of RNA sample. Make sure the final volume in each tube is 200 μl. Gently vortex for 2-3 sec to avoid bubbles.

(7) Incubate at room temperature for 2 min. Protect from light.

(8) Load the sample tubes into a Qubit® Fluorometer and test the sample concentration by performing the RNA High Sensitivity Detection Program.

Application Notes

(1) Protect from light during storage to avoid quenching of fluorescent dyes.

(2) For all reagents and standards in this kit, please mix thoroughly before use by gently inverting tube. Centrifuge for 1-2 sec to collect the reagents to the bottom of tube.

(3) Carefully pipetting of exact volume is critical to ensure accurate quantification. Please use calibrated pipettes for the assay.

(4) Please perform the assay at room temperature. All the kit components to room temperature before use. DO NOT hold the tubes for assay in hands for a long time.

(5) The working solution in Step 4 should be prepared fleshly and used within 3 hours, to avoid fluorescence quenching.

(6) To avoid degradation of RNA standards, use RNA-free consumables for the experiment and place the standards at 2-8 °C after the end of the experiment.


* For Research Use Only. Not for use in diagnostic procedures.